Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.8753701

- Product Categories
- Friendly Links
Information Name: | Supply of online power quality monitor |
Published: | 2012-02-23 |
Validity: | 30 |
Specifications: | |
Quantity: | 1.00 |
Price Description: | |
Detailed Product Description: | First, the design features 1, the GPRS wireless transmission function, and Ethernet remote transmission, anywhere know the real-time data of the various monitoring points, and through the remote control technology, to do at any time on any one monitoring point to modify the settings and do special testing. 2, can be in any place at any time to view the data recorded by the HDGC3580, and detailed in-depth analysis on the host computer. 3, where abnormal electrical events occur, HDGC3580 the fastest alarm, through the raw data can be quickly investigated and dealt with on the computer equipment number and location problems. 4, the company continued to optimize the monitoring terminal program, customers can easily monitor terminal program updates through remote download and install. 5, built a large-capacity flash memory disk, ensure that the length of recording time and record the integrity of the data. Second, the functional Power quality parameter monitoring 1, measure three-phase three-wire three-phase four-wire (three-voltage, current) voltage, current, frequency, and record their trends 2, measure three-phase four-wire power system three-phase active power, apparent power, reactive power, power factor and record the trend of the three-phase active power. 3, to measure three-phase four-wire electrical system imbalance, and record trends. 4, three-phase four-wire (three voltage and current) to 25 harmonics, and its total harmonic distortion can be measured. And record one of the first harmonic trend. 5, measure the voltage fluctuation and flicker. Systems Management: 1, data management The basic measurement data: See the result data stored in the basic measurement functions. Harmonic data: View the saved data in the harmonic measurement function. Power data: View the results of data saved in the power measurements. Three-phase unbalanced data: to view the saved data in the three-phase unbalance measurement functions. Wave recording the event log: view saved data in the event recording function. 2, the measurement correction Zero point correction: correction of each channel zero. The sensor settings: set current sensor. The instrument should be preceded by where the sensor type is set with the actual use of the sensor. 3, system settings Select language: Chinese / English. Time setting: Set the instrument clock. 4, the version of the statement View the software version of the instrument. 5, the software update Upgrading the instrument. Third, technical indicators Measurable range measurement accuracy instructions Voltage / current / frequency three-phase voltage: 10 ~ 700V (rms) Zero line voltage: 1 ~ 70V (True RMS) Three-phase current: 0 ~ (True RMS, optional current sensor) Neutral current: 0 ~ (True RMS, optional current sensor) Frequency: 40 ~ 70Hz Voltage: ± 0.5% Current: ± 0.5% Frequency: ± 0.01Hz here for A-phase voltage and frequency as the measuring frequency Harmonic measurement voltage harmonics: harmonic 1 to 50 harmonic Current harmonics: harmonic, a 50-harmonic voltage harmonics: ± 0.1 (% f) of Current harmonics: ± 1% Power Measurement active: 0.05 ~ 700 kW , As in: 0.05 ~ 700KVA Reactive Power: 0.05 ~ 700KVAR Power factor: 0.00 to 1.00 Active energy: 0.01 ~ 10000kWh. Apparent energy: 0.01 ~ 10000kVAh Reactive power: 0.01 ~ 10000kVARh Average power factor: 0.00 ~ 1.00 active: ± 2% Apparent: ± 2% Reactive: ± 2% Power Factor: reading ± 0.005 Active energy: ± 2% Apparent energy: ± 2% Reactive energy: ± 2% Average power factor: reading ± 0.005 Unbalanced three-phase fundamental voltage: 10 ~ 700V (rms) Fundamental current: 0.5 ~ (True RMS) Fundamental frequency: 40 ~ 70Hz Phase angle: 0 ~ 360o Imbalance degree: 0.0% ~ 100% Voltage: 0.5% Current: 0.5% Frequency: reading ± 0.01Hz Phase angle: reading ± 0.3 o Voltage unbalance: ± 0.2 here of reading ± 0.2 current imbalance in the degree of: reading the A-phase voltage and frequency as the total measurement frequency Monitoring records may be recorded parameters: three-phase voltage, phase current, neutral current, voltage harmonics (THD, 1 to 25 harmonics), the current harmonics (THD, 1 to 25 harmonics) unbalanced three-phase, active power, power factor, fluctuations, flicker records long = (instrument can record the maximum number of data x to save the time interval) / 60 minutes the instrument can record the maximum number of data = 18635 Save time intervals: 3S ~ 30MIN record length: 15 hours - 388 days collection interval is set to 3 seconds, 15.5 hours can be monitored, sampling intervals set 388 days (three seconds to 30 minutes, 30 minutes can be monitored continuously adjustable) Sudden jump in the sudden drop in voltage swells, voltage sag, and a temporary power outage can record up to 40 events Fluctuations in voltage fluctuation: 0.1% to 10.0% measurement error: ± 5% Flicker Flicker short-term flicker long short time flicker measurement error: ± 5% for a long time flicker measurement error: ± 5% Digital oscilloscope, phase voltage, phase current, the zero line voltage and neutral current transient waveform of the maximum sampling frequency: 200KHz Minimum sampling frequency: 100Hz Model HDGC3580 Size 225 × 155 × 150 memory 128M bit Display touch screen, 5.7-inch 320 × 240 color graphic LCD power supply voltage of 14.4V (Lithium battery) Communication interface GPRS / LAN weight 2KG |
Admin>>>
You are the 8233 visitor
Copyright © GuangDong ICP No. 10089450, Wuhan Heng power measurement Electric Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 8233 visitor
Copyright © GuangDong ICP No. 10089450, Wuhan Heng power measurement Electric Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility