Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.8753701

- Product Categories
- Friendly Links
Information Name: | Supply three-phase power quality tester |
Published: | 2012-02-23 |
Validity: | 30 |
Specifications: | |
Quantity: | 1.00 |
Price Description: | |
Detailed Product Description: | First, an overview HDGC3561 portable three-phase power quality analyzers, dedicated portable detection and analysis of the quality of grid operation. Can provide electricity in the operation of harmonic analysis and power quality analysis, equipped with large-capacity memory, long-term data acquisition testing the power grid, while with PC application software, upload the collected data to your computer for easy various analyzes. Second, the functional 1, voltage, current, frequency: Measurable phase voltage, the zero line voltage, phase current, neutral current, and frequency. 2, the harmonic measure: Measurable to the 50th harmonic, the measurement results, including the harmonic voltage and harmonic current amplitude, voltage harmonic distortion (total harmonic distortion rate), and various voltage harmonics / current harmonic content ratio; harmonic bar graph is displayed. 3, the power measurement: Measurable three-phase apparent power, active power, reactive power, power factor, three-phase power. 4, three-phase imbalance measurement: Measure the three-phase voltage unbalance degree and positive sequence, negative sequence, zero sequence voltage; degree of unbalanced three-phase current and positive sequence, negative sequence, zero sequence current; to display the voltage vector, current vector. 5, the inrush current: can record at least 40 inrush current events. Fluctuations / flicker: fluctuations in short-term flicker, long-term flicker measurement. 7, swells / plummeted: to record the voltage dips, swells the event, and can record up to 40 events. Monitoring records: a long record of basic power quality parameters of the (steady state), the recording time interval adjustable from 3 seconds to 30 minutes. 9, a digital oscilloscope: can be used to view the voltage / current signal waveform. Third, the design features A color touch screen display, easy to operate. 2, high-performance lithium battery power supply for a long time. Three, three-phase troubleshooting tool: the actual measurements for each power system parameter: voltage, current, frequency, power, power consumption (energy), unbalance and flicker, harmonics and inter-harmonics, capture like a sudden jump in The sudden drop in these events, transients, interruptions and rapid voltage changes. 4, HDGC3561 three-phase power quality analyzer is manufactured with reference GB/T14549-93 power quality utility grid harmonic GB IEC61000-4-31A-class standards. 5, U disk can use extended memory, extended recording time. Fourth, the typical application ① front-end troubleshooting: the screen displays the failure of rapid diagnosis, allowing the system to resume normal work ② predictive maintenance: to detect and prevent power quality problems in the event of a lockout before ③ quality of service: the user to introduce the line to check the power quality ④ long analysis: detection of difficult to find or intermittent failures (5) load research: check the electrical system capacity before the increase in load ⑥ energy assessment: energy consumption before and after the transformation of quantitative assessment to prove the effect of saving equipment Five technical indicators Measurable range measurement accuracy instructions Voltage / current / frequency three-phase voltage: 10 ~ 700V (rms) Zero line voltage: 1 ~ 70V (True RMS) Three-phase current: 0 ~ 1000A (True RMS, matching the 1000A current sensor) Zero line current: 0 ~ 25A (True RMS Option 25A current sensor) Frequency: 40 ~ 70Hz Voltage: ± 0.5% Current: ± 0.5% Frequency: ± 0.01Hz Here for the A-phase voltage and frequency as the measurement frequency Harmonic measurement voltage harmonics: harmonic, a 50th harmonic. Current Harmonics: THD, 1 to 50th harmonic. Voltage harmonics: ± 0.1 (f) of Current harmonics: ± 1% Power Measurement active: 0.05 ~ 700 kW , As in: 0.05 ~ 700KVA Reactive Power: 0.05 ~ 700KVAR Power factor: 0.00 to 1.00 Active energy: 0.01 ~ 10000kWh. Apparent energy: 0.01 ~ 10000kVAh Reactive power: 0.01 ~ 10000kVARh Average power factor: 0.00 ~ 1.00 active: ± 2% Apparent: ± 2% Reactive: ± 2% Power Factor: reading ± 0.005 Active energy: ± 2% Apparent energy: ± 2% Reactive energy: ± 2% Average power factor: reading ± 0.005 Unbalanced three-phase fundamental voltage: 10 ~ 700V (rms) Fundamental current: 0.5 ~ 1000A (True RMS) Fundamental frequency: 40 ~ 70Hz Phase angle: 0 ~ 360o Imbalance degree: 0.0% ~ 100% Voltage: 0.5% Current: 0.5% Frequency: reading ± 0.01Hz Phase angle: reading ± 0.3 o Voltage imbalance: reading ± 0.2 Current imbalance: reading ± 0.2 Here for A-phase voltage and frequency as the total measurement frequency Monitoring records Can record the parameters: Three-phase voltage, phase current, neutral current, voltage harmonics (THD, 1 to 25 harmonics), Current Harmonics (THD, harmonics 1 to 25), unbalanced three-phase, active power, power factor, fluctuations and flicker Record length = (instrument can record the maximum number of data x to save the time interval) / 60 minutes Instrument can record the maximum number of data = 18635 Save time intervals: 3S ~ 30MIN Record length: 15 hours to 388 days Collection interval set to 3 seconds, the monitoring of 15.5 hours, the collection interval is set 388 days (three seconds to 30 minutes, 30 minutes can be monitored continuously adjustable) Swells plunged Voltage swells, voltage sag, and temporary power outages Can record up to 40 events Fluctuations in voltage fluctuation: 0.1% to 10.0% measurement error: ± 5% Flicker short-term flicker Short period of time long-term flicker flicker measurement error: ± 5% Long time flicker measurement error: ± 5% Digital oscilloscope, phase voltage, phase current, the zero line voltage and neutral current transient waveform of the maximum sampling frequency: 200KHz Minimum sampling frequency: 100Hz Model HDGC3561 Size 290 × 110 × 55mm Display touch screen, 5.7-inch 320 × 240 color graphic LCD Communication interface USB Weight 1.6KG Memory 128M (bit) |
Admin>>>
You are the 8233 visitor
Copyright © GuangDong ICP No. 10089450, Wuhan Heng power measurement Electric Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 8233 visitor
Copyright © GuangDong ICP No. 10089450, Wuhan Heng power measurement Electric Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility