Information Name: | Supply power quality analyzer |
Published: | 2012-02-23 |
Validity: | 30 |
Specifications: | |
Quantity: | 1.00 |
Price Description: | |
Detailed Product Description: | First, an overview HDGC3530 three-phase power quality analyzer is the reference to "GB/T14549-93 power quality utility grid harmonic GB IEC 61000-4-31 A, class standards of design and manufacture, detection and analysis of the quality of grid operation dedicated handheld Product instruments. Power operation of harmonic analysis and power quality data analysis, while the impact on power in the process of starting and stopping of large electrical equipment monitoring the entire process. Equipped with large-capacity memory, long-term data acquisition testing the power grid, with PC applications software, upload the collected data to a computer to facilitate a variety of analysis. Second, the functional Basic measuring function: Measurement of voltage, current, frequency, and record trends. Harmonic measurement function: 1 to 50 harmonic measure three-phase four-wire (three voltage and current), and its total harmonic distortion. And record one of the first harmonic trend. Power measurement function: Measure three-phase four-wire electrical system in three-phase active power, apparent power, reactive power, power factor and record the trend of the three-phase active power. Imbalance measurement function: Measure the three-phase four-wire electrical system imbalance, and record trends. Monitoring and recording functions: Monitoring and recording function can be three-phase four-wire power system three-phase voltage, phase current, neutral current (THD, 1 to 25 harmonics), the current harmonics (THD, 1 to 25 harmonic ), unbalanced three-phase, active power, power factor and other parameters of the long measurement record. Digital oscilloscope function: Can detect three-phase four-wire electrical system voltage and current waveforms changes, and can record a moment of voltage or current waveform. Third, the design features Small size, light weight and easy to carry High-performance lithium batteries for a long time supply Complete three-phase troubleshooting tool: the actual measurements for each power system parameter: voltage, current, frequency, power, power consumption (energy), unbalance and flicker, harmonics and inter-harmonics to capture sudden drop in like a sudden jump in These events, transients, interruptions and rapid voltage changes. Fourth, the typical application ① front-end troubleshooting: the screen displays the failure of rapid diagnosis, allowing the system to resume normal work ② predictive maintenance: to detect and prevent power quality problems in the event of a lockout before ③ quality of service: the user to introduce the line to check the power quality ④ long analysis: detection of difficult to find or intermittent failures (5) load research: check the electrical system capacity before the increase in load ⑥ energy assessment: energy consumption before and after the transformation of quantitative assessment to prove the effect of saving equipment Five technical indicators Project Parameters Input impedance: 1MΩ, 20pF Measurement range and accuracy of 1) Voltage: 10 ~ 700V (rms) 2) Current: 1A, 10A, 100A, 1000A (select the corresponding current clamp sensor) 3) Frequency: 30 ~ 80HZ ± 0.01HZ 4) harmonic measurement: 1 to 50th harmonic Surge Current: 2000A (optional current sensor 1000A) Peak voltage: 1000V Memory capacity: 128M (Bit) Display: 320 × 240 color graphic LCD Communications Interface: USB , Measuring the indicators of the function Measurable range measurement accuracy instructions Voltage / current / frequency three-phase voltage: 10 ~ 700V (rms) Zero line voltage: 1 ~ 70V (True RMS) Three-phase current: 0 ~ 1000A (True RMS, matching the 1000A current sensor) Zero line current: 0 ~ 25A (True RMS Option 25A current sensor) Frequency: 40 ~ 70Hz Voltage: ± 0.5% Current: ± 0.5% Frequency: ± 0.01Hz Here for the A-phase voltage and frequency as the measurement frequency Harmonic measurement voltage harmonics: harmonic 1 to 50 harmonic Current harmonics: harmonic, a 50th harmonic voltage harmonics: ± 0.1% (% f) Current harmonics: 1% Power Measurement active: 0.05 ~ 700 kW , As in: 0.05 ~ 700KVA Reactive Power: 0.05 ~ 700KVAR Power factor: 0.00 to 1.00 Active energy: 0.01 ~ 10000kWh. Apparent energy: 0.01 ~ 10000kVAh Reactive power: 0.01 ~ 10000kVARh Average power factor: 0.00 ~ 1.00 active: ± 2% Apparent: ± 2% Reactive: ± 2% Power factor: ± 0.005% Active energy: ± 2% Apparent energy: ± 2% Reactive energy: ± 2% Average power factor: ± 0.005% Unbalanced three-phase fundamental voltage: 0 ~ 007V (rms) Fundamental current: 0.5 ~ 1000A (True RMS) Fundamental frequency: 40 ~ 70Hz Phase angle: 0 ~ 360o Imbalance degree: 0.0% ~ 100% Voltage: ± 0.5% Current: ± 0.5% Frequency: ± 0.01% Phase angle: ± 0.3% Imbalance degree: ± 0.2% Here for A-phase voltage and frequency as the total measurement frequency Monitoring records Can be recorded parameters: three-phase voltage, phase current, neutral current, voltage harmonics (THD, 1 to 50 harmonics), the current harmonics (THD, 1 to 50 harmonics), three-phase imbalance, active power, power factor, volatility, flash change can be recorded when the long = (instrument recording the number of data x to save time interval) / 60 minutes the instrument can record the maximum number of data = 18635 Record length: 15 hours to 388 days Collection interval is set to 3 seconds, you can monitor the 15.5 hours, 388 days of the acquisition interval set to 30 minutes can be monitored (three seconds to 30 minutes adjustable) Sudden jump in the sudden drop in voltage swells, voltage sag, and a temporary power outage can record up to 40 events Fluctuations in voltage fluctuation range: 0.1% ~ 10.0% measurement error ≤ ± 5% Flicker Short-term flicker, flicker long short time flicker measurement error: ± 5% Long time flicker measurement error: ± 5% Digital oscilloscope Three-phase voltage, four-wire current transient waveform of the maximum sampling frequency: 200KHz Minimum sampling frequency: 100Hz Size 278 * 152 * 85mm Weight 1.6Kg |
Admin>>>
You are the 8233 visitor
Copyright © GuangDong ICP No. 10089450, Wuhan Heng power measurement Electric Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 8233 visitor
Copyright © GuangDong ICP No. 10089450, Wuhan Heng power measurement Electric Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility